Multitronic MT-4

Device for electric therapy with possibility of additional laser therapy.

Description

[et_pb_section bb_built=”1″][et_pb_row][et_pb_column type=”4_4″][et_pb_text _builder_version=”3.16.1″]

GENERAL CHARACTERISTICS
  • Modern device for double-channel electrotherapy and laser biostimulation
  • Two possible treatments at the same time
  • Big, color graphic screen (4,3”) with touch panel.
  • User-friendly operation by touch screen and buttons.
  • Ergonomic treatment probes
  • Convenient probe holder
  • Esthethic design
  • Ready to use programs for typical illnesses
  • User’s own programs – with easy to use screen keyboard
  • Individual regulation of all treatment parameters
  • Function of fan control which minimizes energy consuption and generated noise
  • Counters of number and time of treatments
  • May be used as portable

 

Electrotherapy features

  • Two independent treatment circuits
  • CC or CV workmode
  • Microcurrents mode
  • Setting of different wave modulations (electro-gymnastics)
  • Setting of sequence of diadynamic currents
  • Electrode test function
  • User friendly electro-diagnostics (I/t curve points, automatic calculation of coefficients); last 5 tests are stored in memory
  • Safe reaction to power supply disruption
  • Detection of break in treatment circuit

 

Lasertherapy features
  • Continuous and pulsed work mode
  • Repeat dose function
  • Sensor for power check of probes

 

ACCESSORIES

Standard
User’s manual
Set of electrodes, pads, fixing bands
Electrotherapy treatment cable
Spare fuses
Warning labels

Optional
Laser probes: point and cluster models
Protective eyewear for laser treatments
Different types of electrodes and other electrotherapy accessories
Transportation bag

 

Current types

Multitronic MT-4 allows treatments with the following current types:

  • Interferential: static (clasic), dynamic, izoplanar, dipol vector, 2-pole (premodulated) and interrupted
  • Diadynamic according to Bernard, types DF, MF, RS, MM, CP, LP, CPiso, LPiso (with sequence setting)
  • Paresis stimulation (medium frequency currents in shape of triangle, rectangle, sine and trapezoid – each unipolr and bipolar
  • Spastic paresis stimulation in double-channel mode (tonolysis)
  • TENS, including so called “irritating” modulation
  • TENS BURST
  • HVPS stimulation
  • Kotz current (Russian stimulation
  • Träbert current – Ultra Reiz – (UR) (2-5)
  • Microcurrent
  • CC or CV mode
  • Faradic and neofaradic
  • Wave modulation or electrogymnastics with wide regulation range
  • Ionthophoresis
  • Galvanic / DC

 

Technical data of laser probes

Point probes
Type of probe S-1N S-2N S-3N
Wavelength 905 nm 660 nm 808 nm
Pulse power 50 W 40 mW 400 mW
Frequency 5-5000Hz 5-9999Hz 5-9999Hz
Mean power (0,1–50)mW (1-40)mW (1-400)mW
Pulse energy 10 µJ —- —-
Width of pulse 200ns —- —-
Cluster probes
Type of probe SP-1 SP-2 SP-3
Wavelength 660 nm 660 nm / 808 nm 808 nm
Number of diodes 9 5 / 4 9
Single diode power 40 mW 40 mW / 160 mW 160 mW
Total power 360 mW 840 mW 1440 mW
Frequency 5-9999Hz 5-9999Hz 5-9999Hz
Area of treatment 50 cm2 50 cm2 50 cm2

[/et_pb_text][/et_pb_column][/et_pb_row][/et_pb_section]

HEADQUARTERS
Stare mesto 100
739 61 Trinec
CZECHIA
INTERNATIONAL SALES
Miroslav Kaleta
Tel: +420 739 209 421
E-mail: info@fysiomed.eu

Product inquiry